Cevatpaşa Mahallesi Derya Sokak No 27 / B Bayrampaşa / İstanbul
0212 537 49 57
0532 720 43 51

Aksa Diesel Generator Sets

Star InactiveStar InactiveStar InactiveStar InactiveStar Inactive
 
Cummins Generator AC 350

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications.

All generator sets are factory build, and production tested.

Cummins Generator
General Characteristics
Model Name: AC 350
Frequency ( Hz ): 50
Fuel Type: Diesel
Engine Made and Model: CUMMINS - QSL9-G5
Alternator Made and Model: Mecc Alte - ECO 38-3L/4 A
Control Panel Model: DSE 7320
Canopy: MS 60
3 Phase 50 Hz PF 0.8
STANDBY RATING ( ESP ):
  • Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source.
  • ESP is in accordance with ISO 8528-1.
  • Overload is not allowed.
PRIME RATING ( PRP ):
  • Applicable for supplying power to varying electrical load for unlimited hours.
  • PRP is in accordance with ISO 8528-1.
  • 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
VOLTAGE
Voltage: 400/231
STANDBY RATING ( ESP )
kVA: 350
kW: 280.0
PRIME RATING ( PRP )
kVA: 300
kW: 240.0
Standby Amper
Standby Amper: 505.20
ENGINE SPECIFICATIONS
Engine: CUMMINS
Engine Model: QSL9-G5
NO. OF CYLINDERS AND BUILD: 6 cylinders - in line
BORE AND STROKE mm: 114 X 145
TOTAL DISPLACEMENT L: 8.8
Aspiration: Turbo Charged and AfterCooled
COMPRESSION RATIO: 16.8:1
RATED SPEED ( RPM ) d/dk: 1500
OIL CAPACITY L: 26.5
Standby Power ( kW/HP ): 310/415
Prime Power ( kW/HP ): 268/359
Block Heater QTY: 1
Block Heater Power ( Watt ): 3000
Fuel Type: Diesel
Injection Type and System: Direct
Type of Fuel Pump: HPCR (High Pressure Common Rail)
Governor System: ECM
Operating Voltage ( Vdc ): 24 Vdc
Battery and Capacity ( Qty / Ah ): 2x85
Charge Alternator ( A ): 70
Cooling Method: Water Cooled
Cooling Fan Air Flow ( m3 / min ): 475
Coolant Capacity ( engine only / with radiator ) ( lt ): 11/28.6
Air Filter: Dry Type
Fuel Cons Prime With %100 Load ( lt / hr ): 63
Fuel Cons Prime With %75 Load ( lt / hr ): 46
Fuel Cons Prime With %50 Load ( lt / hr ): 31
ALTERNATOR SPECIFICATIONS
Manufacturer: Mecc Alte
Alternator Made and Model: ECO 38-3L/4 A
Frequency ( Hz ): 50
Power ( kVA ): 350
DESIGN: 4 Pole, Brushless
VOLTAGE: 400
Phase: 3
A.V.R.: DSR
Voltage Regulation ( + / - ): 1
Insulation System: H
Protection: IP23
Rated Power Factor: 0.8
WEIGHT COMP. GENERATOR ( Kg ): 905
COOLING AIR ( m³ / min ): 32
Open Type
DRY WEIGHT ( kg ) ( kg ): 2665
LENGTH ( mm ): 2901
WIDTH ( mm ): 1300
HEIGHT ( mm ): 1939
TANK CAPACITY ( lt ) ( Lt ): 470
CANOPY
CANOPY: MS 60
DRY WEIGHT ( kg ) ( kg ): 3485
LENGTH ( mm ): 3960
WIDTH ( mm ): 1356
HEIGHT ( mm ): 2167
TANK CAPACITY ( lt ) ( Lt ): 470
STANDARD SPECIFICATIONS
STANDARD SPECIFICATIONS:
  • Water cooled, Diesel engine
  • Radiator with mechanical fan
  • Protective grille for rotating and hot parts
  • Electric starter and charge alternator
  • Starting battery (with lead acid) including rack and cables
  • Engine coolant heater
  • Base frame design incorporates an integral fuel tank and anti-vibration isolators
  • Flexible fuel connection hoses
  • Single bearing, class H alternator
  • Industrial exhaust silencer and steel bellows supplied separately(for open sets)
  • Static battery charger
  • Manual for application and installation
  • Generators Sets’ voltage and frequency regulation comply with ISO 8528-5
  • Generators Sets’ can take 100% load at one step according to NFPA110
OPTIONAL EQUIPMENTS
ENGINE:
  • Remote Radiator Cooling
  • Fuel-Water Seperator Filter
  • Oil heater
ALTERNATOR:
  • Anti-Condensation Heater
  • Over sized alternator
  • Main line circuit breaker
CONTROL SYSTEM:
  • Automatic synchronising and power control system ( multi gen-set Parallel )
  • Paralel system with mains.
  • Transition synchronization with mains
  • Remote annunciator panel
  • Remote relay output
  • Alarm output relays
  • Remote communication with modem
  • Earth fault, single set
  • Charge Ammeter
TRANSFER SWITCH:
  • Three or four pole contactor
  • Three or four pole motor operated circuit breaker
OTHER ACCESSORIES:
  • Main Fuel Tank
  • Automatic or manual fuel filling system
  • Manual oil drain pump
  • Low and high fuel level alarm
  • Residential silencer
  • Enclosure: weater protective or sound attenuated
  • Duct adapter ( on radiator)
  • Inlet and outlet motorised louvers
  • Inlet and outlet acoustic baffles
  • Trailer
  • Tool kit for maintenance
  • 1500/3000 hours maintenance kit
  • Double wall chassis
  • Supplied with oil and coolant - 30 °C
  • Battery isolating switch