Cevatpaşa Mahallesi Derya Sokak No 27 / B Bayrampaşa / İstanbul
0212 537 49 57
0532 720 43 51

Aksa Diesel Generator Sets

User Rating: 5 / 5

Star ActiveStar ActiveStar ActiveStar ActiveStar Active
 
Cummins Generator APD 145 C

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications.

All generator sets are factory build, and production tested.

Cummins Generator
General Characteristics
Model Name: APD 145 C
Frequency ( Hz ): 50
Fuel Type: Diesel
Engine Made and Model: CUMMINS - 6BTAA5.9G2
Alternator Made and Model: Aksa - AK 4110
Control Panel Model: DSE 6020
Canopy: ASM 5A
3 Phase 50 Hz PF 0.8
STANDBY RATING ( ESP ):
  • Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source.
  • ESP is in accordance with ISO 8528-1.
  • Overload is not allowed.
PRIME RATING ( PRP ):
  • Applicable for supplying power to varying electrical load for unlimited hours.
  • PRP is in accordance with ISO 8528-1.
  • 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
VOLTAGE
Voltage: 400/231
STANDBY RATING ( ESP )
kVA: 145
kW: 116
PRIME RATING ( PRP )
kVA: 132
kW: 105.60
Standby Amper
Standby Amper: 209.30
ENGINE SPECIFICATIONS
Engine: CUMMINS
Engine Model: 6BTAA5.9G2
NO. OF CYLINDERS AND BUILD: 6 cylinders - in line
BORE AND STROKE mm: 102 X 120
TOTAL DISPLACEMENT L: 5.90
Aspiration: Turbo Charged and Charge Air Cooled
COMPRESSION RATIO: 17.3:1
RATED SPEED ( RPM ) d/dk: 1500
OIL CAPACITY L: 16.4
Standby Power ( kW/HP ): 130/174
Prime Power ( kW/HP ): 120/161
Block Heater QTY: 1
Fuel Type: Diesel
Injection Type and System: Direct
Type of Fuel Pump: BYC PB
Governor System: Electronic
Operating Voltage ( Vdc ): 24 Vdc
Battery and Capacity ( Qty / Ah ): 2x60
Cooling Method: Water Cooled
Cooling Fan Air Flow ( m3 / min ): 148
Coolant Capacity ( engine only / with radiator ) ( lt ): 34.4
Air Filter: Dry Type
Fuel Cons Prime With %100 Load ( lt / hr ): 30
Fuel Cons Prime With %75 Load ( lt / hr ): 23
Fuel Cons Prime With %50 Load ( lt / hr ): 16
ALTERNATOR SPECIFICATIONS
Manufacturer: Aksa
Alternator Made and Model: AK 4110
Frequency ( Hz ): 50
Power ( kVA ): 137,5
DESIGN: Brushless
VOLTAGE: 400
Phase: 3
A.V.R.: AS460
Voltage Regulation ( + / - ): 1,5%
Insulation System: H
Protection: IP22
Rated Power Factor: 0.8
WEIGHT COMP. GENERATOR ( Kg ): 492
COOLING AIR ( m³ / min ): 30,84
Open Type
DRY WEIGHT ( kg ) ( kg ): 1360
LENGTH ( mm ): 2290
WIDTH ( mm ): 1000
HEIGHT ( mm ): 1474
TANK CAPACITY ( lt ) ( Lt ): 195
CANOPY
CANOPY: ASM 5A
DRY WEIGHT ( kg ) ( kg ): 1800
LENGTH ( mm ): 3316
WIDTH ( mm ): 1063
HEIGHT ( mm ): 1715
TANK CAPACITY ( lt ) ( Lt ): 195
STANDARD SPECIFICATIONS
STANDARD SPECIFICATIONS:
  • Water cooled, Diesel engine
  • Radiator with mechanical fan
  • Protective grille for rotating and hot parts
  • Electric starter and charge alternator
  • Starting battery (with lead acid) including rack and cables
  • Engine coolant heater
  • Base frame design incorporates an integral fuel tank and anti-vibration isolators
  • Flexible fuel connection hoses
  • Single bearing, class H alternator
  • Industrial exhaust silencer and steel bellows supplied separately(for open sets)
  • Static battery charger
  • Manual for application and installation
OPTIONAL EQUIPMENTS
ENGINE:
  • Fuel-Water Seperator Filter
  • Oil heater
ALTERNATOR:
  • Anti-Condensation Heater
  • Main line circuit breaker
CONTROL SYSTEM:
  • Charge Ammeter
TRANSFER SWITCH:
  • Three or four pole contactor
  • Three or four pole motor operated circuit breaker
OTHER ACCESSORIES:
  • Main Fuel Tank
  • Enclosure: weater protective or sound attenuated
  • Trailer
  • Tool kit for maintenance